Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 30-34, 2015.
Article in Chinese | WPRIM | ID: wpr-637094

ABSTRACT

ObjectiveTo investigate the features of normal and psoriasis skin on ultrasound biomicroscopy (UBM) and explore the method of thickness measurement.MethodsUsing 50 MHz ultrasound probe of biological microscope, ultrasonographic observation and ultrasonic thickness measurement were conducted in 90 normal adults and 40 psoriasis patients. Innormal patients, ultrasound evaluations were performed at 10 different parts of the body skin.ResultsOn sonogram, the normal skin showed a “sandwich” structure with two parallel hyperechoic bands and the middle isoechoic dots and short liens. The sonograms of the psoriasis skin showed obviously thickened epidermis and dermis, disordered internal structure and clear boundary from adjacent normal skin. The range of the epidermis’ thickness measurement was between the medial forearm (0.12±0.03) mm and the palm (0.29±0.15) mm. The range of dermal thickness measurement was between the back hand (1.18±0.32) mm and parasternal (1.55±0.21) mm. Psoriasis skin was thicker than the uninvolved skin (P<0.001). And the dermis’ thickness of uninvolved skin in psoriasis patients was thicker than that of the normal adults (P<0.001).ConclusionNormal adult’s epidermis, dermis and skin appendages can be shown clearly using 50 MHz ultrasound biomicroscopy. And ultrasound biomicroscopy canaccurately measure the thickness of dermis and epidermis, which provides the basis for the diagnosis and treatment of psoriasis.

2.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 25-29, 2015.
Article in Chinese | WPRIM | ID: wpr-637085

ABSTRACT

ObjectiveTo discuss the application value of high frequency ultrasound (HFUS) characteristics, acoustic radiation force impulse (ARFI) imaging technology and contrast-enhanced ultrasound (CEUS) in the diagnosis of soft tissue hemangioma.MethodsTo retrospectively analyze the clinical data of 44 cases of soft tissue hemangioma that were treated in Capital Medical University Affiliate Beijing Chaoyang Hospital from August, 2013 to May, 2014, and to analyze the difference between the characteristics of HFUS, ARFI and CEUS in soft tissue hemangioma and normal surrounding tissue.ResultsHFUS shows the features of morphological diversity of sinus shape expansion tube structure, unclear boundary, irregular configuration, compressibility and partial strong echo in the phlebolith. Color Doppler ultrasound (CDFI), detects abundant interphase red-blue bloodstream signal slowly and consistently. The blood signal is strengthened after partial compression. CDFI shows more vein spectrum in the lesion. The discrepancy of comparison between VTQ and SWV value of soft tissue hemangioma and surrounding muscular tissue possesses statistical significance [(1.082±0.183) m/svs (1.414±0.331) m/s,P<0.01]. Ultrasound contrast can show the relationship between diseased region and surrounding tissue clearly, which is beneficial to the selection of operation method and prognosis.ConclusionThrough conventional two-dimensional ultrasound and high frequency CDFI, and further combining the acoustic pulse radiation ARFI technology and CEUS technology, the soft tissue hemangioma can’t only be more accurately diagnosed, but also provides more reliable diagnostic basis for clinic.

3.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 559-563, 2015.
Article in Chinese | WPRIM | ID: wpr-637503

ABSTRACT

Objective To evaluate the value of virtual touch quantization (VTQ) imaging in diagnosis of IgA nephropathy. Methods The clinical data of 85 patients with IgA nephropathy were analyzed, who were treated in Capital Medical University Affiliate Beijing Chaoyang Hospital from December 2013 to July 2014. The patients who was with critical condition, unable to cooperate and with other pathological types were excluded. Finally 108 kidneys of IgA nephropathy with mesangial cell hyperplasia in 54 cases were included into the study. Meanwhile 108 kidneys in 54 volunteers who took the health physical examination in our hospital were taken as healthy controls. VTQ was performed in middle part of kidney and the measurements of shear wave velocity (SWV) was recorded. The mean SWV of renal parenchyma and collecting system was compared in different groups. Results The mean SWV measurement of renal parenchyma and collecting system in control group were (2.13±0.13) m/s, (1.15±0.02) m/s;the results in IgA nephropathy group were (3.07±0.62) m/s, (1.12±0.29) m/s. The mean SWV of renal collecting system was lower than that of renal parenchyma (t=-14.481, P<0.001). The mean SWV of renal parenchyma and collecting system in IgA Nephropathy group was higher than that in control group (t=-54.01, P<0.001). The renal parenchyma VTQ value positively correlated with the degree of renal insufficiency for patients with chronic kidney disease (CKD) (F=798.70, P<0.001). The interlobular arterial resistance index (RI) increased gradually with CKD stage, but no statistical differences were found. Conclusion In terms of early diagnosis and clinical staging, VTQ technology has some diagnostic value in evaluation of renal parenchymal damage for patients with IgA nephropathy.

4.
Chinese Journal of Ultrasonography ; (12): 981-983, 2010.
Article in Chinese | WPRIM | ID: wpr-385634

ABSTRACT

Objective To study the value of time intensity curve of contrast enhanced ultrasound in the discrimination of benign and malignant soft tissue tumors. Methods Thirty-seven cases of soft tissue tumors were carried out contrast-enhanced ultrasound examination. The region of interest in the dynamic images were chosen to carry out Gamma-Variate curve fitting through Q-LAB software and made a quantitative analysis. Then they were compared with pathological diagnosis to analyze the ultrasound imaging performance of benign and malignant tumors and their characteristics of micro-irrigation. Results Thirty-seven cases of soft tissue tumors were pathologically diagnosed 21 cases of benign and malignant in 16 cases. The perfusion of benign tumors were mainly uniformity (19/21) or potentialization (2/21). The perfusion of malignant tumors were mainly uniformity (10/16) or nonuniformity (6/16). There were no significant differences in time to peak(TTP) and arrival time of contrast agent(AT) between benign and malignant tumors( P >0.05). The upslope rate(A) and the derived peak intensity(DPI) in benign group were significantly less than malignant group ( P <0.05). Conclusions Time-intensity curve analysis of contrast-enhanced ultrasound showed that benign and malignant soft tissue tumors were different in perfusion,and it will be of a certain value for the clinical differential diagnosis.

5.
Chinese Journal of Ultrasonography ; (12): 950-952, 2009.
Article in Chinese | WPRIM | ID: wpr-392041

ABSTRACT

Objective To study the relationship between the cerebral artery stenosis and the carotid artery elasticity in the ischemia stroke patients by echo-tracking technique.Methods Ninety-two ischemia stroke patients were divided into both the mild cerebral arteries stenosis and moderate-severe cerebral arteries stenosis groups.CT angiography was performed to evaluate the stenosis of cerebral artery.The changes of the carotid diameter during cardiac cycles were obtained by echo-tracking technique and the quantitative parameters of pressure-strain elastic modulus (Ep),stiffness (β) and arterial compliance (AC) were calculated automatically. Results①There were significant differences (P<0.05) between the ischemia stroke patient group and the normal adults group in β,Ep and AC.② There were significant differences (P<0.05) between the mild cerebral arteries stenosis groups and the moderate-severe cerebral arteries stenosis groups in β and Ep.AC was lower in patients with the mild cerebral arteries stenosis groups than that in the moderate-severe cerebral arteries stenosis groups.Conclusions The carotid artery elasticity in ischemia stroke patients were significantly different from normal adults.In the ischemia stroke patients,the stiffer the carotid artery was,the higher the likelihood of moderate-severe cerebral stenosis was.

6.
Chinese Journal of Ultrasonography ; (12): 336-338, 2008.
Article in Chinese | WPRIM | ID: wpr-401126

ABSTRACT

Objective To explore the anatomic character of brachial plexus nerve by ultrasonography,and provide a basis for ultrasound-guided brachial plexus block.Methods Twenty-four healthy volunteers were chosen for high-frequency sonography examination,the features of brachial plexus distributions were studied in the axilla location and the interscalene location.Results Brachial plexus of all the 24 cases were detected.At the axilla level,main braches of brachial plexus nerves were very close to the axillary artery.At the interscalene level,the brachial plexus was consistently found between the scalenus anterior and medius muscles in the interscalene groove.Conclusions Using high-frequency sonography,the main braches of brachial plexus can be observed clearly.

SELECTION OF CITATIONS
SEARCH DETAIL